perm filename DIAG.LST[KL,SYS] blob
sn#268524 filedate 1977-03-15 generic text, type T, neo UTF8
;MAINDEC-10-I108.INP
IDENTIFICATION
--------------
PRODUCT CODE: MAINDEC-10-I108.INP
PRODUCT NAME: DECSYSTEM10 KL10 DIAGNOSTIC LIST
VERSION: 4.8
DATE: AUGUST 1976
AUTHOR: JOHN R. KIRCHOFF
MAINTAINED BY: DECSYSTEM10 RELEASE ENGINEERING
DIAGNOSTIC MAGTAPE CREATED BY MAGTAP VER 0.1 ON 23-AUG-76 AT 14:22
0. MAGTAP RDI 20-FEB-76 MAGTAPE READ-IN BOOTSTRAP
;MAGTAPE UTILITY PROGRAMS AND DIRECTORY FILES
1. MAGTAP SAV 0.1 5-MAR-65 MAGTAPE CREATOR
2. MAGMON SAV 0.10 26-FEB-76 MAGTAPE MONITOR
3. MAGTAP MTA 23-AUG-76 INTERNAL MAGTAPE DIRECTORY
4. MAGTAP DIR 23-AUG-76 PRINTABLE MAGTAPE DIRECTORY
5. I108 INP 23-AUG-76 MAGTAPE INPUT FILE - 1080 REV 8
6. SUBRTN A10 0.11 3-JUN-76 PDP-10 SUBRTN
7. KLDDT A10 0.10 26-FEB-76 PDP-10 DDT
8. I208 INP 23-AUG-76 MAGTAPE INPUT FILE - 2040 REV 8
;CONSOLE
9. KLDCP BIN 22-JUN-76 KL10 DIAGNOSTIC CONSOLE
10. KLDCPU A11 0.11 22-JUN-76 KL10 CONSOLE UTILITY
11. CDUMP A11 0.11 22-JUN-76 KL10 CONSOLE CORE DUMP UTILITY
12. KLDCP HLP 22-JUN-76 HELP FILE
13. KLDTBT BIN 27-JAN-76 KLDCP DECTAPE BOOT
14. KLRXBT BIN 27-JAN-76 KLDCP FLOPPY BOOT
15. UPD2 BIN 27-JAN-76 UPDATE PROGRAM #2
16. XTECO BIN 27-JAN-76 TEXT EDITOR
;SYSTEM #1
17. U RAM 126 18-DEC-75 KL10 MICROCODE
18. B CMD 26-FEB-76 KL10 DIAGNOSTIC RUN FILE
19. BT CMD 22-JUN-76 KL10 BOOT TEN RUN FILE
20. CONFG CCL 4-DEC-75 MEMORY CONFIGURATION RUN FILE
21. KLLD CCL 13-FEB-76 KL10 "SUBRTN" & "KLDDT" LOAD
22. CONEX A11 0.10 6-APR-76 CONSOLE EXTENSION & MEMORY CONFIGURATOR
23. CONEX HLP 9-APR-76 HELP FILE
24. SUBRTN A10 0.11 3-JUN-76 PDP-10 SUBROUTINE PROGRAM
25. KLDDT A10 0.10 26-FEB-76 PDP-10 DDT
26. DIAMON A10 0.11 1-JUN-76 PDP-10 DIAGNOSTIC MONITOR
27. MAGMON A10 0.10 26-FEB-76 PDP-10 MAGTAPE MONITOR
;SYSTEM #2
28. KLCPU CMD 24-FEB-76 FUNCTIONAL COMMAND RUN FILE
29. KLCPUO CMD 24-FEB-76 OLD FUNCTIONAL COMMAND RUN FILE
30. KLPROC CMD 13-FEB-76 "DIAMON" FUNCTIONAL RUN FILE
31. KLPROO CMD 13-FEB-76 "DIAMON" OLD FUNCTIONAL RUN FILE
32. KLUSR CMD 13-FEB-76 "DIAMON" USER FUNCTIONAL RUN FILE
33. KLUSRO CMD 13-FEB-76 "DIAMON" OLD USER FUNCTIONAL RUN FILE
34. X1 CCL 4-DEC-75 EXTERNAL MEMORY CONFG - 1 WAY INTERLEAVE
35. X2 CCL 4-DEC-75 EXTERNAL MEMORY CONFG - 2 WAY INTERLEAVE
36. X4 CCL 4-DEC-75 EXTERNAL MEMORY CONFG - 4 WAY INTERLEAVE
37. TRACE A11 0.8 18-FEB-76 DIAGNOSTIC SIGNAL TRACE UTILITY
38. TRACE HLP 3-SEP-75 HELP FILE
39. DGQDD A11 1 29-JUN-76 DLDP - DL11E MONITOR
40. DGQDE A11 1 21-JUN-76 DN87S LOADER UTILITY PROGRAM
;SPECIAL #1
41. MARGN CMD 8-APR-76 CMD FILE TO MARGIN TEST INTERNAL MEMORIES
42. MARGNR CMD 8-APR-76 CMD FILE TO MARGIN TEST RELOCATED INTERNAL MEMORIES
43. CONFG1 CCL 2-APR-76 INTERNAL MEMORY CONFG - 1 WAY INTERLEAVE
44. CONFGR CCL 6-APR-76 CCL FILE TO RELOCATE INTERNAL MEMORIES
45. MEMLOD CCL 8-APR-76 CCL FILE TO TURN OFF MARGINS AND LOAD DDMMG
46. PATTST CCL 8-APR-76 CCL FILE TO PATCH DDMMG TO RUN A PATTERN TEST
47. ADRTST CCL 8-APR-76 CCL FILE TO PATCH DDMMG TO RUN AN ADDRESS TEST
48. WCPTST CCL 8-APR-76 CCL FILE TO PATCH DDMMG TO RUN WORST-CASE PATTERNS
49. LOMARC CCL 5-APR-76 CCL FILE TO SET LOW CURRENT MARGINS
50. HIMARC CCL 5-APR-76 CCL FILE TO SET HIGH CURRENT MARGINS
51. LOMARS CCL 5-APR-76 CCL FILE TO SET LOW STROBE MARGINS
52. HIMARS CCL 5-APR-76 CCL FILE TO SET HIGH STROBE MARGINS
53. LOMART CCL 5-APR-76 CCL FILE TO SET LOW THRESHOLD MARGINS
54. HIMART CCL 5-APR-76 CCL FILE TO SET HIGH THRESHOLD MARGINS
55. MGNOFF CCL 2-APR-76 CCL FILE TO CLEAR MARGINS
;KL10 PROCESSOR FUNCTIONAL DIAGNOSTICS (NEW)
56. DFKAA A10 0.1 25-AUG-75 BASIC INSTRUCTIONS #1
57. DFKAB A10 0.1 11-SEP-75 BASIC INSTRUCTIONS #2
58. DFKAC A10 0.1 11-SEP-75 BASIC INSTRUCTIONS #3
59. DFKAD A10 0.1 11-SEP-75 BASIC INSTRUCTIONS #4
60. DFKBA A10 0.1 11-SEP-75 BASIC INSTRUCTION RELIABILITY
61. DFKCA A10 0.1 8-SEP-75 ADVANCED INSTRUCTIONS
62. DFKDA A10 0.1 11-SEP-75 CPU/PI/MEMORY RELIABILITY
63. DFKEA A10 0.1 2-MAY-75 PAGING HARDWARE
64. DFKEB A10 0.1 2-MAY-75 MUUO & USER MODE
65. DFKFB A10 0.1 2-MAY-75 INSTRUCTION TIMING
66. DFKFD A10 0.2 7-JUL-75 I/O BUS TESTER
67. DFDTE A10 1.7 9-JAN-76 DTE20 10/11 INTERFACE
;KL10 PROCESSOR FUNCTIONAL DIAGNOSTICS (OLD)
68. DEKAA A10 0.1 29-APR-75 BASIC INSTRUCTIONS #1
69. DEKAB A10 0.1 29-APR-75 BASIC INSTRUCTIONS #2
70. DEKAC A10 0.1 29-APR-75 BASIC INSTRUCTIONS #3
71. DEKAD A10 0.1 29-APR-75 BASIC INSTRUCTIONS #4
72. DEKAE A10 0.1 29-APR-75 BASIC INSTRUCTIONS #5
73. DEKAF A10 0.1 29-APR-75 BASIC INSTRUCTIONS #6
74. DEKAG A10 0.1 29-APR-75 BASIC INSTRUCTIONS #7
75. DFKAH A10 0.2 7-JUL-75 BASIC INSTRUCTIONS #8
76. DEKAI A10 0.1 29-APR-75 BASIC INSTRUCTIONS #9
77. DEKAJ A10 0.1 29-APR-75 BASIC INSTRUCTIONS #10
78. DEKAK A10 0.1 29-APR-75 BASIC INSTRUCTIONS #11
79. DEKAL A10 0.1 29-APR-75 BASIC INSTRUCTIONS #12
80. DEKAM A10 0.1 29-APR-75 BASIC INSTRUCTIONS #13
81. DEKBA A10 0.1 29-APR-75 BASIC INSTRUCTION RELIABILITY #1
82. DEKBB A10 0.1 29-APR-75 BASIC INSTRUCTION RELIABILITY #2
83. DEKBC A10 0.1 29-APR-75 BASIC INSTRUCTION RELIABILITY #3
84. DEKBD A10 0.1 29-APR-75 BASIC INSTRUCTION RELIABILITY #4
85. DEKCA A10 0.1 29-APR-75 ADVANCED INSTRUCTIONS #1
86. DEKCB A10 0.1 29-APR-75 ADVANCED INSTRUCTIONS #2
87. DEKCC A10 0.1 29-APR-75 ADVANCED INSTRUCTIONS #3
88. DEKCD A10 0.1 29-APR-75 ADVANCED INSTRUCTIONS #4
89. DEKCE A10 0.1 29-APR-75 ADVANCED INSTRUCTIONS #5
90. DFKDC A10 0.2 7-JUL-75 INTERRUPT RELIABILITY
;PDP-10 MEMORY DIAGNOSTICS
91. DDMMD A10 0.1 12-JUN-75 MEMORY
92. DDMME A10 0.1 16-JUN-75 BLT/MEMORY EXERCISER
93. DDMMF A10 0.1 16-JUN-75 FLOATING ONES/ZEROS
94. DDMMG A10 0.1 12-JUN-75 4096K MEMORY
;PDP-10 BASIC PERHIPERAL DIAGNOSTICS
95. DDLPA A10 0.2 4-SEP-75 LINE PRINTER
96. DDLAA A10 0.2 11-JUN-76 LA36 TERMINAL
97. DDVTA A10 0.2 11-JUN-76 VIDEO TERMINAL
;PDP-10 RH20 CONTROLLER DIAGNOSTIC
98. DFRHB A10 0.10 11-JUN-76 RH20 DEVICE-LESS
;PDP-10 TM02-TU16/TU45 MAGNETIC TAPE DIAGNOSTICS
99. DFTUE A10 0.2 30-JUN-76 BASIC & RELIABILITY
100. DFTUF A10 0.2 10-JUN-76 RH20 MULTI-DRIVE EXERCISER
101. DDTUH A10 0.2 7-JUN-76 RH10 MULTI-DRIVE EXERCISER
102. DDTUG A10 0.2 30-JUN-76 RH10 TM02/TU16 BASIC/RELIABILITY DIAGNOSTIC
;PDP-10 RH20/RP04 (MASSBUS) DISK DIAGNOSTICS
103. DFRPH A10 0.1 10-DEC-75 RH20/RP04 BASIC DEVICE
104. DDRPI A10 0.3 16-AUG-76 RH20/RP04/5/6 RELIABILITY
;PDP-10 RH20/RP06 (MASSBUS) DISK DIAGNOSTICS
105. DFRPK A10 0.1 10-JUN-76 RH20/RP06 BASIC DEVICE
;PDP-10 EXERCISER DIAGNOSTICS
106. DFSXA A10 0.2 30-JUL-76 2040 SYSTEM EXERCISER
;PDP-10 USER-MODE SYSTEM DIAGNOSTIC SUPPORT PROGRAMS
107. DIAMON SAV 0.11 3-JUN-76 PDP-10 DIAGNOSTIC MONITOR
108. RP04LD ABS 6-FEB-76 RP04 KLDCP BOOT
109. PMAKER HLP 3-FEB-76 RP04 DIAGNOSTIC PACK HELP FILE
110. PMAKER EXE 1-JUL-76 RP04 DIAGNOSTIC PACK CREATOR
111. P108 CMD 23-AUG-76 RP04 CREATION FILE - 1080 REV 8
112. P208 CMD 23-AUG-76 RP04 CREATION FILE - 2040 REV 8
113. SYS CMD 12-JUL-76 RP04 SYSTEM CREATION FILE
114. WHEEL SAV 103.4 7-JAN-76 RP04 CREATION PRIVILEGE PROGRAM
;PDP-10 USER-MODE FIELD SERVICE SUPPORT
115. ERROR RPT 23-JAN-76 PM FEEDBACK REPORT FORM
116. SCHED SAV 0.420 28-JAN-76 PM SCHEDULING PROGRAM
117. SCHED HLP 26-JAN-76 PM SCHEDULING HELP FILE
118. README HLP 23-JAN-76 PM PACKAGE HELP FILE
119. SCHED INP 27-JAN-76 PM SCHEDULING TABLE
;DECSYSTEM10 1080 PERHIPERAL DIAGNOSTICS
;PDP-10 BASIC PERHIPERALS
120. DDCPA A10 0.2 2-APR-76 CARD PUNCH
121. DDCRA A10 0.2 4-NOV-75 CARD READER
122. DDDKA A10 0.1 4-SEP-75 DK10 REAL TIME CLOCK
123. DDDTA A10 0.1 30-MAR-76 DT03-CC SWITCH CONTROLLER - A
124. DDDTB A10 0.1 30-MAR-76 DT03-CC SWITCH CONTROLLER - B
125. DDXYA A10 0.1 30-MAR-76 CALCOMP PLOTTER
;PDP-10 DECTAPE DIAGNOSTICS
126. DDTDA A10 12-JUN-75 TD10 DIAGNOSTIC #1
127. DDTDB A10 12-JUN-75 TD10 DIAGNOSTIC #2
128. DDTDC A10 12-JUN-75 TD10 DIAGNOSTIC #3
129. DDTDD A10 0.2 21-OCT-75 DECTAPE RELIABILITY
130. DDTDE A10 12-JUN-75 DECTAPE CERTIFICATION
;PDP-10 TM10B MAGNETIC TAPE DIAGNOSTICS
131. DDTMD A10 12-JUN-75 TM10B DIAGNOSTIC #1
132. DDTME A10 12-JUN-75 TM10B DIAGNOSTIC #2
133. DDTMF A10 12-JUN-75 TM10B DIAGNOSTIC #3
134. DDTMH A10 2-JUL-75 TM10B RELIABILITY
;PDP-10 TU70 MAGNETIC TAPE DIAGNOSTICS
135. DDDXA A10 0.3 4-NOV-75 DX10 DATA CHANNEL #1
136. DDDXB A10 0.3 4-NOV-75 DX10 DATA CHANNEL #2
137. DDTUA A10 0.3 4-NOV-75 TU70 SUBSYSTEM
138. DDTUB A10 0.2 4-NOV-75 TU70 RELIABILITY
139. DXDXA A8 0.1 30-OCT-75 DX10 MICRO-DIAGNOSTIC
140. DXMPA A8 2(3) 6-OCT-75 DX10 I/O MICROPROCESSOR MICROCODE
141. DJKKA A8 0.2 9-OCT-75 PDP-8A DIAGNOSTIC CPU
142. DJMSA A8 0.1 9-OCT-75 PDP-8A DIAGNOSTIC MEMORY
143. DJEXA A8 0.1 9-OCT-75 PDP-8A DIAGNOSTIC EXERCISER
;PDP-10 RH10 CONTROLLER DIAGNOSTIC
144. DDRHA A10 0.3 11-MAY-76 RH10 DEVICE-LESS
;PDP-10 RH10/RS04 (MASSBUS) DISK DIAGNOSTICS
145. DDRSB A10 13-AUG-75 RH10/RS04 DISK TRANSFER & RELIABILITY
146. DDRSC A10 0.1 9-JAN-76 RH10/RS04 BASIC DEVICE
;PDP-10 RH10/RP04 (MASSBUS) DISK DIAGNOSTICS
147. DDRPF A10 12-JUN-75 RH10/RP04 STATIC & MAINTENANCE
148. DDRPH A10 0.1 10-DEC-75 RH10/RP04 BASIC DEVICE
;PDP-10 RH10/RP06 (MASSBUS) DISK DIAGNOSTICS
149. DDRPK A10 0.1 4-JUN-76 RH10/RP06 BASIC DEVICE
;PDP-10 RP10C/RP02/RP03 DISK DIAGNOSTICS
150. DDRPA A10 12-JUN-75 INTERFACE #1
151. DDRPB A10 12-JUN-75 INTERFACE #2
152. DDRPC A10 12-JUN-75 RELIABILITY
;PDP-10 DISK SUBSYSTEM USER-MODE
153. DDRPD SAV 500.151 2-OCT-75 USER MODE DISK PERFORMANCE
;PDP-10 COMMUNICATIONS DIAGNOSTICS
154. DDDCA A10 0.2 21-OCT-75 DC10
155. DDDLA A10 0.3 28-JUN-76 DL10 DIAGNOSTIC #1
156. DDDLB A10 12-JUN-75 DL10 DIAGNOSTIC #2
157. DXDLC BIN 6-OCT-72 DL10 PDP-11 SIDE
158. DDDLG A10 12-JUN-75 DL10 PDP-11 LOADER
159. DDDLH A10 0.1 2-APR-76 DL10 EXEC-MODE DOWNLINE LOADER
160. DDDMA A10 0.1 11-MAY-76 PDP10/PDP11 MEMORY LINK TEST
;PDP-10 EXERCISER DIAGNOSTICS
161. DDQCB A10 0.4 13-FEB-76 MEMORY PORT INTERACTION
162. DDDFA A10 12-JUN-75 DF10/DF10C
;PDP-10 COMMUNICATIONS (DA28) DIAGNOSTICS
163. DDDAE A10 0.2 3-JUN-76 DA28 DIAGNOSTIC
164. DDDAF A10 0.3 3-JUN-76 DA28 DIAGNOSTIC TEST MONITOR
165. DXDAG BIN 12-FEB-76 DA28F INTERPROCESSOR BUFFER INTERFACE
166. DXDAH BIN 8-MAR-76 DA28-F/H INTERACTIVE PDP-11 SIDE
167. DXDAI BIN 7-MAY-75 DA28F BASIC TEST
168. DXDAJ BIN 5-JUN-75 DA28A INTERACTION TEST
169. DXDAN BIN 8-MAR-76 DA28-H INTERACIVE PDP-15 SIDE
170. DXDMB BIN 24-SEP-75 DMA10 MEMORY LINK TEST
171. DCDAM SAV 0.4 9-JUN-75 BOOTSTRAP PDP8, 11 OR 15 VIA DA28
;KL10 PROCESSOR HARDWARE DIAGNOSTICS
172. KLDIAG CMD 3-MAR-76 DIAGNOSTIC COMMAND RUN FILE
173. DIACON HLP 8-APR-75 DIAGNOSTIC EXECUTIVE HELP FILE
174. DGDTE A11 0.7 8-SEP-75 DTE20 10-11 INTERFACE
175. DGKAA A11 0.8 3-MAR-76 E-BOX PART 1
176. DGKAB A11 0.8 3-MAR-76 E-BOX PART 2
177. EBOX RAM 12 3-MAR-76 E-BOX PART 2 DIAGNOSTIC MICROCODE
178. DGKBA A11 0.8 25-FEB-76 M-BOX BASIC
179. DGKBB A11 0.8 1-MAR-76 MEMORY CONTROL & MEMORY
180. MBOX RAM 126 18-DEC-75 M-BOX DIAGNOSTIC MICROCODE
181. DGKBC A11 0.8 1-MAR-76 PAGING LOGIC
182. DGMCA A11 0.8 24-FEB-76 M-BOX MCA20 CACHE OPTION
183. DGKCA A11 0.8 1-MAR-76 METER BOARD
184. DGKBD A11 0.8 16-MAR-76 MBOX CHANNEL CONTROL
185. DGKBE A11 0.8 16-MAR-76 MBOX CHANNEL LOOPBACK
186. DS1017 A11 0.8 16-FEB-76 DIAG SIGNAL TRANSLATOR DF 100-117
187. DS1257 A11 0.8 16-FEB-76 DIAG SIGNAL TRANSLATOR DF 120-157
188. DS1677 A11 0.8 16-FEB-76 DIAG SIGNAL TRANSLATOR DF 160-177
;KL10 HARDWARE SUPPORT FILES
;DGKBA
189. A7M1 TIC 0.8 17-FEB-76
190. A7M2 TIC 0.8 17-FEB-76
191. A7M3 TIC 0.8 17-FEB-76
192. A10M1 TIC 3.7 17-FEB-76
193. A10M2 TIC 3.7 17-FEB-76
194. A10M4 TIC 0.8 17-FEB-76
195. A16M1 TIC 0.8 17-FEB-76
196. A16M2 TIC 0.8 17-FEB-76
197. A16M3 TIC 0.8 17-FEB-76
198. A16M4 TIC 0.8 17-FEB-76
199. A18M1 TIC 0.8 17-FEB-76
200. A18M2 TIC 0.8 17-FEB-76
201. A19M1 TIC 0.8 17-FEB-76
202. A19M2 TIC 0.8 17-FEB-76
203. A19M3 TIC 3.7 17-FEB-76
204. A19M4 TIC 0.8 17-FEB-76
205. A19M7 TIC 0.8 17-FEB-76
206. A19M8 TIC 0.8 17-FEB-76
207. A19M9 TIC 3.7 17-FEB-76
208. A19M10 TIC 0.8 17-FEB-76
209. A19M13 TIC 0.8 17-FEB-76
210. A19M14 TIC 0.8 17-FEB-76
211. A19M15 TIC 3.7 17-FEB-76
212. A19M16 TIC 0.8 17-FEB-76
213. A19M19 TIC 0.8 17-FEB-76
214. A19M20 TIC 0.8 17-FEB-76
215. A19M21 TIC 3.7 17-FEB-76
216. A19M22 TIC 0.8 17-FEB-76
217. A20M1 TIC 3.7 17-FEB-76
218. A20M2 TIC 0.8 17-FEB-76
219. A21M1 TIC 0.8 17-FEB-76
220. A21M2 TIC 0.8 17-FEB-76
221. A21M3 TIC 3.7 17-FEB-76
222. A23M1 TIC 0.8 17-FEB-76
223. A23M2 TIC 3.7 17-FEB-76
224. A23M3 TIC 3.7 17-FEB-76
225. A23M4 TIC 0.8 17-FEB-76
226. A23M5 TIC 3.7 17-FEB-76
227. A23M6 TIC 0.8 17-FEB-76
228. A23M7 TIC 0.8 17-FEB-76
229. A23M8 TIC 0.8 17-FEB-76
230. A23M9 TIC 3.7 17-FEB-76
;KL10 HARDWARE SUPPORT FILES
;DGMCA
231. K2M1 TIC 0.8 25-FEB-76
232. K3M1 TIC 0.8 25-FEB-76
233. K3M2 TIC 0.8 25-FEB-76
234. K3M3 TIC 0.8 25-FEB-76
235. K4M1 TIC 0.8 25-FEB-76
236. K4M4 TIC 0.8 25-FEB-76
237. K8M1 TIC 0.8 25-FEB-76
238. K8M2 TIC 0.8 25-FEB-76
239. K8M3 TIC 0.8 25-FEB-76
240. K9M1 TIC 0.8 25-FEB-76
241. K9M4 TIC 0.8 25-FEB-76
242. K13M1 TIC 0.8 25-FEB-76
243. K13M2 TIC 0.8 25-FEB-76
244. K13M3 TIC 0.8 25-FEB-76
245. K14M1 TIC 0.8 25-FEB-76
246. K14M4 TIC 0.8 25-FEB-76
247. K18M1 TIC 0.8 25-FEB-76
248. K18M2 TIC 0.8 25-FEB-76
249. K18M3 TIC 0.8 25-FEB-76
250. K19M1 TIC 0.8 25-FEB-76
251. K19M4 TIC 0.8 25-FEB-76
;KL10 HARDWARE SUPPORT FILES
;DGMCA (CON'T)
252. K23M1 TIC 0.8 25-FEB-76
253. K23M2 TIC 0.8 25-FEB-76
254. K26M1 TIC 0.8 25-FEB-76
255. K26M2 TIC 0.8 25-FEB-76
256. K26M3 TIC 0.8 25-FEB-76
257. K26M4 TIC 0.8 25-FEB-76
258. K26M5 TIC 0.8 25-FEB-76
259. K26M6 TIC 0.8 25-FEB-76
260. K26M7 TIC 0.8 25-FEB-76
261. K26M8 TIC 0.8 25-FEB-76
262. K26M9 TIC 0.8 25-FEB-76
263. K26M10 TIC 0.8 25-FEB-76
264. K26M11 TIC 0.8 25-FEB-76
265. K26M12 TIC 0.8 25-FEB-76
266. K27M1 TIC 0.8 25-FEB-76
267. K27M2 TIC 0.8 25-FEB-76
268. K30M1 TIC 0.8 25-FEB-76
269. K30M2 TIC 0.8 25-FEB-76
270. K30M3 TIC 0.8 25-FEB-76
271. K30M4 TIC 0.8 25-FEB-76
272. K30M5 TIC 0.8 25-FEB-76
273. K30M6 TIC 0.8 25-FEB-76
274. K30M7 TIC 0.8 25-FEB-76
275. K30M8 TIC 0.8 25-FEB-76
276. K30M9 TIC 0.8 25-FEB-76
277. K30M10 TIC 0.8 25-FEB-76
278. K30M11 TIC 0.8 25-FEB-76
279. K30M12 TIC 0.8 25-FEB-76
280. K31M1 TIC 0.8 25-FEB-76
281. K31M2 TIC 0.8 25-FEB-76
;KL10 HARDWARE SUPPORT FILES
;DGMCA (CON'T)
282. K34M1 TIC 0.8 25-FEB-76
283. K34M2 TIC 0.8 25-FEB-76
284. K34M3 TIC 0.8 25-FEB-76
285. K34M4 TIC 0.8 25-FEB-76
286. K34M5 TIC 0.8 25-FEB-76
287. K34M6 TIC 0.8 25-FEB-76
288. K34M7 TIC 0.8 25-FEB-76
289. K34M8 TIC 0.8 25-FEB-76
290. K34M9 TIC 0.8 25-FEB-76
291. K34M10 TIC 0.8 25-FEB-76
292. K34M11 TIC 0.8 25-FEB-76
293. K34M12 TIC 0.8 25-FEB-76
294. K35M1 TIC 0.8 25-FEB-76
295. K35M2 TIC 0.8 25-FEB-76
296. K38M1 TIC 0.8 25-FEB-76
297. K38M2 TIC 0.8 25-FEB-76
298. K38M3 TIC 0.8 25-FEB-76
299. K38M4 TIC 0.8 25-FEB-76
300. K38M5 TIC 0.8 25-FEB-76
301. K38M6 TIC 0.8 25-FEB-76
302. K38M7 TIC 0.8 25-FEB-76
303. K38M8 TIC 0.8 25-FEB-76
304. K38M9 TIC 0.8 25-FEB-76
305. K38M10 TIC 0.8 25-FEB-76
306. K38M11 TIC 0.8 25-FEB-76
307. K38M12 TIC 0.8 25-FEB-76
308. K41M1 TIC 0.8 25-FEB-76
309. K41M2 TIC 0.8 25-FEB-76
310. K41M3 TIC 0.8 25-FEB-76
311. K41M4 TIC 0.8 25-FEB-76
;KL10 HARDWARE SUPPORT FILES
;DGMCA (CON'T)
312. K42M1 TIC 0.8 25-FEB-76
313. K42M2 TIC 0.8 25-FEB-76
314. K42M3 TIC 0.8 25-FEB-76
315. K42M4 TIC 0.8 25-FEB-76
316. K42M5 TIC 0.8 25-FEB-76
317. K42M6 TIC 0.8 25-FEB-76
318. K42M7 TIC 0.8 25-FEB-76
319. K42M8 TIC 0.8 25-FEB-76
320. K42M9 TIC 0.8 25-FEB-76
321. K43M1 TIC 0.8 25-FEB-76
322. K43M2 TIC 0.8 25-FEB-76
323. K43M3 TIC 0.8 25-FEB-76
324. K43M4 TIC 0.8 25-FEB-76
325. K44M1 TIC 0.8 25-FEB-76
326. K44M2 TIC 0.8 25-FEB-76
327. K45M1 TIC 0.8 25-FEB-76
328. K45M2 TIC 0.8 25-FEB-76
329. K45M3 TIC 0.8 25-FEB-76
330. K45M4 TIC 0.8 25-FEB-76
331. K45M5 TIC 0.8 25-FEB-76
332. K47M1 TIC 0.8 25-FEB-76
333. K49M1 TIC 0.8 25-FEB-76
334. K49M2 TIC 0.8 25-FEB-76
;KL10 HARDWARE SUPPORT FILES
;DGKBC
335. P3M1 TIC 0.8 2-MAR-76
336. P3M2 TIC 0.8 2-MAR-76
337. P3M3 TIC 2-MAR-76
338. P3M4 TIC 0.8 2-MAR-76
339. P4M1 TIC 0.8 2-MAR-76
340. P4M2 TIC 0.8 2-MAR-76
341. P5M1 TIC 0.8 2-MAR-76
342. P5M2 TIC 0.8 2-MAR-76
343. P9M1 TIC 0.8 2-MAR-76
344. P10M1 TIC 0.8 2-MAR-76
345. P10M3 TIC 0.8 2-MAR-76
346. P10M7 TIC 0.8 2-MAR-76
347. P10M12 TIC 0.8 2-MAR-76
;KL10 HARDWARE SUPPORT FILES
;DGKBD
348. C4C2 TIC 0.8 17-MAR-76
349. C4C12 TIC 0.8 17-MAR-76
350. C4C22 TIC 0.8 17-MAR-76
351. C4C32 TIC 0.8 17-MAR-76
352. C4C42 TIC 0.8 17-MAR-76
353. C4C52 TIC 0.8 17-MAR-76
354. C4C62 TIC 0.8 17-MAR-76
355. C4C72 TIC 0.8 17-MAR-76
356. C5C2 TIC 0.8 17-MAR-76
357. C5C3 TIC 0.8 17-MAR-76
358. C9C2 TIC 0.8 17-MAR-76
359. C9C12 TIC 0.8 17-MAR-76
360. C9C22 TIC 0.8 17-MAR-76
361. C9C32 TIC 0.8 17-MAR-76
362. C9C42 TIC 0.8 17-MAR-76
363. C9C52 TIC 0.8 17-MAR-76
364. C9C62 TIC 0.8 17-MAR-76
365. C9C72 TIC 0.8 17-MAR-76
366. C9C4 TIC 0.8 17-MAR-76
367. C9C15 TIC 0.8 17-MAR-76
368. C9C25 TIC 0.8 17-MAR-76
369. C9C35 TIC 0.8 17-MAR-76
370. C9C45 TIC 0.8 17-MAR-76
371. C9C55 TIC 0.8 17-MAR-76
372. C9C65 TIC 0.8 17-MAR-76
373. C9C75 TIC 0.8 17-MAR-76
374. C15C1 TIC 0.8 17-MAR-76
375. C15C11 TIC 0.8 17-MAR-76
376. C15C21 TIC 0.8 17-MAR-76
377. C15C31 TIC 0.8 17-MAR-76
378. C15C41 TIC 0.8 17-MAR-76
379. C15C51 TIC 0.8 17-MAR-76
380. C15C61 TIC 0.8 17-MAR-76
381. C15C71 TIC 0.8 17-MAR-76
382. C17C1 TIC 0.8 17-MAR-76
383. C17C2 TIC 0.8 17-MAR-76
384. C17C3 TIC 0.8 17-MAR-76
385. C17C11 TIC 0.8 17-MAR-76
386. C17C12 TIC 0.8 17-MAR-76
387. C17C13 TIC 0.8 17-MAR-76
388. C17C21 TIC 0.8 17-MAR-76
389. C17C22 TIC 0.8 17-MAR-76
390. C17C23 TIC 0.8 17-MAR-76
391. C17C31 TIC 0.8 17-MAR-76
392. C17C32 TIC 0.8 17-MAR-76
393. C17C33 TIC 0.8 17-MAR-76
394. C17C41 TIC 0.8 17-MAR-76
395. C17C51 TIC 0.8 17-MAR-76
396. C17C61 TIC 0.8 17-MAR-76
397. C17C71 TIC 0.8 17-MAR-76
398. C17C42 TIC 0.8 17-MAR-76
399. C17C52 TIC 0.8 17-MAR-76
400. C17C62 TIC 0.8 17-MAR-76
401. C17C72 TIC 0.8 17-MAR-76
402. C17C43 TIC 0.8 17-MAR-76
403. C17C53 TIC 0.8 17-MAR-76
404. C17C63 TIC 0.8 17-MAR-76
405. C17C73 TIC 0.8 17-MAR-76
;KL10 HARDWARE ISOLATION FILES
;DGKAA
406. E1 A11 0.7 11-FEB-76
407. E2 A11 0.7 7-FEB-76
408. E3 A11 0.7 7-FEB-76
409. E4 A11 0.7 7-FEB-76
410. E5 A11 0.7 7-FEB-76
411. E6 A11 0.7 7-FEB-76
412. E7 A11 0.7 11-FEB-76
413. E8 A11 0.7 7-FEB-76
414. E9 A11 0.7 7-FEB-76
415. E10 A11 0.7 7-FEB-76
416. E11 A11 0.7 7-FEB-76
417. E12 A11 0.7 19-FEB-76
418. E13 A11 0.7 7-FEB-76
419. E14 A11 0.7 7-FEB-76
420. E15 A11 0.7 7-FEB-76
421. E16 A11 0.7 7-FEB-76
422. E17 A11 0.7 7-FEB-76
423. E18 A11 0.7 7-FEB-76
424. E19 A11 0.7 7-FEB-76
425. E20 A11 0.7 7-FEB-76
426. E21 A11 0.7 7-FEB-76
427. E22 A11 0.7 7-FEB-76
428. E23 A11 0.7 7-FEB-76
429. E24 A11 0.7 7-FEB-76
430. E25 A11 0.7 7-FEB-76
431. E26 A11 0.7 7-FEB-76
432. E27 A11 0.7 7-FEB-76
433. E28 A11 0.7 7-FEB-76
434. E29 A11 0.7 7-FEB-76
435. E30 A11 0.7 7-FEB-76
436. E31 A11 0.7 7-FEB-76
437. E32 A11 0.7 7-FEB-76
438. E33 A11 0.7 7-FEB-76
439. E34 A11 0.7 11-FEB-76
440. E35 A11 0.7 11-FEB-76
441. E36 A11 0.7 11-FEB-76
442. E37 A11 0.7 11-FEB-76
443. E38 A11 0.7 11-FEB-76
;KL10 HARDWARE ISOLATION FILES
;DGKAB
444. F1 A11 0.7 11-FEB-76
445. F2 A11 0.7 11-FEB-76
446. F3 A11 0.7 11-FEB-76
447. F4 A11 0.7 11-FEB-76
448. F5 A11 0.7 11-FEB-76
449. F6 A11 0.7 11-FEB-76
450. F7 A11 0.7 11-FEB-76
451. F8 A11 0.7 11-FEB-76
452. F9 A11 0.7 11-FEB-76
453. F10 A11 0.7 11-FEB-76
454. F11 A11 0.7 11-FEB-76
455. F12 A11 0.7 11-FEB-76
456. F13 A11 0.7 11-FEB-76
457. F14 A11 0.7 11-FEB-76
458. F15 A11 0.7 11-FEB-76
459. F16 A11 0.7 7-FEB-76
460. F17 A11 0.7 7-FEB-76
461. F18 A11 0.7 7-FEB-76
462. F19 A11 0.7 7-FEB-76
463. F20 A11 0.7 7-FEB-76
464. F21 A11 0.7 7-FEB-76
465. F22 A11 0.7 7-FEB-76
466. F23 A11 0.7 7-FEB-76
467. F24 A11 0.7 7-FEB-76
468. F25 A11 0.7 7-FEB-76
469. F26 A11 0.7 11-FEB-76
470. F27 A11 0.7 11-FEB-76
471. F28 A11 0.7 11-FEB-76
472. F29 A11 0.7 11-FEB-76
473. F30 A11 0.7 11-FEB-76
474. F31 A11 0.7 11-FEB-76
475. F32 A11 0.7 11-FEB-76
476. F33 A11 0.7 11-FEB-76
477. F34 A11 0.7 11-FEB-76
478. F35 A11 0.7 11-FEB-76
479. F36 A11 0.7 11-FEB-76
480. F37 A11 0.7 11-FEB-76
481. F38 A11 0.7 11-FEB-76
;KL10 HARDWARE ISOLATION FILES
;DGKBA
482. A1 A11 0.8 23-DEC-75
483. A2 A11 0.8 23-DEC-75
484. A3 A11 0.8 23-DEC-75
485. A4 A11 0.8 23-DEC-75
486. A5 A11 0.8 2-JAN-76
487. A6 A11 0.8 23-DEC-75
488. A7 A11 0.8 2-JAN-76
489. A8 A11 0.8 23-DEC-75
490. A9 A11 0.8 23-DEC-75
491. A10 A11 0.8 2-JAN-76
492. A11 A11 0.8 23-DEC-75
493. A12 A11 0.8 23-DEC-75
494. A13 A11 0.8 23-DEC-75
495. A14 A11 0.8 23-DEC-75
496. A15 A11 0.8 11-FEB-76
497. A16 A11 0.8 23-DEC-75
498. A17 A11 0.8 23-DEC-75
499. A18 A11 0.8 23-DEC-75
500. A19 A11 0.8 23-DEC-75
501. A20 A11 0.8 23-DEC-75
502. A21 A11 0.8 23-DEC-75
503. A22 A11 0.8 23-DEC-75
504. A23 A11 0.8 23-DEC-75
505. A24 A11 0.8 23-DEC-75
506. A25 A11 0.8 11-FEB-76
507. A26 A11 0.8 2-JAN-76
508. A27 A11 0.8 11-FEB-76
;KL10 HARDWARE ISOLATION FILES
;DGKBB
509. M1 A11 2.7 9-JAN-76
510. M2 A11 2.7 9-JAN-76
511. M3 A11 2.7 9-JAN-76
512. M4 A11 2.7 9-JAN-76
513. M5 A11 2.7 9-JAN-76
514. M6 A11 2.7 9-JAN-76
515. M7 A11 2.7 9-JAN-76
516. M8 A11 2.7 9-JAN-76
517. M9 A11 2.7 9-JAN-76
518. M10 A11 2.7 9-JAN-76
519. M13 A11 2.7 9-JAN-76
520. M14 A11 2.7 9-JAN-76
521. M15 A11 2.7 9-JAN-76
522. M16 A11 2.7 9-JAN-76
523. M18 A11 2.7 9-JAN-76
524. M19 A11 2.7 9-JAN-76
525. M20 A11 2.7 9-JAN-76
526. M21 A11 2.7 9-JAN-76
527. M23 A11 2.7 9-JAN-76
528. M24 A11 2.7 9-JAN-76
529. M25 A11 2.7 9-JAN-76
530. M26 A11 2.7 9-JAN-76
531. M27 A11 2.7 9-JAN-76
532. M28 A11 2.7 9-JAN-76
533. M29 A11 2.7 9-JAN-76
534. M30 A11 2.7 9-JAN-76
535. M31 A11 2.7 9-JAN-76
536. M32 A11 2.7 9-JAN-76
537. M33 A11 2.7 9-JAN-76
538. M34 A11 2.7 9-JAN-76
539. M35 A11 2.7 9-JAN-76
540. M36 A11 2.7 9-JAN-76
;KL10 HARDWARE ISOLATION ROUTINES
;DGKCA
541. D1 A11 0.8 9-JAN-76
542. D2 A11 0.8 9-JAN-76
543. D3 A11 0.8 9-JAN-76
544. D4 A11 0.8 9-JAN-76
545. D5 A11 0.8 9-JAN-76
546. D6 A11 0.8 9-JAN-76
547. D7 A11 0.8 9-JAN-76
548. D8 A11 0.8 9-JAN-76
549. D9 A11 0.8 9-JAN-76
550. D10 A11 0.8 9-JAN-76
551. D11 A11 0.8 9-JAN-76
552. D12 A11 0.8 9-JAN-76
553. D13 A11 0.8 9-JAN-76
554. D14 A11 0.8 9-JAN-76
555. D15 A11 0.8 9-JAN-76
556. D16 A11 0.8 9-JAN-76
557. D17 A11 0.8 9-JAN-76
558. D18 A11 0.8 9-JAN-76
559. D19 A11 0.8 9-JAN-76
560. D20 A11 0.8 9-JAN-76
561. D21 A11 0.8 9-JAN-76
562. D22 A11 0.8 9-JAN-76
563. D23 A11 0.8 9-JAN-76
564. D24 A11 0.8 9-JAN-76
565. D25 A11 0.8 9-JAN-76
566. D26 A11 0.8 9-JAN-76
567. D27 A11 0.8 1-MAR-76
;PDP-11 11/40 FRONT-END DIAGNOSTICS
568. TCDP BIN 13-FEB-76 DECTAPE LOADER
569. RXDP BIN 13-FEB-76 FLOPPY LOADER
570. UPD2 BIN 27-JAN-76 DEVICE UTILITY PROGRAM
571. XTECO BIN 27-JAN-76 TEXT EDITOR
572. COPY BIN 27-JAN-76 COPY PROGRAM
573. DBQEAB BIN 0.2 12-FEB-76 11/40 CPU
574. DZQMCB BIN 12-FEB-76 MEMORY/PARITY
575. DZBMDF BIN 12-FEB-76 BM873Y ROM
576. DZCDBA BIN 4-JUN-76 CD11/CD20 CARD READER
577. DZDLCA BIN 12-FEB-76 DL11/E
578. DZKWAE BIC 15-FEB-76 KW11-L
579. DZTCBC BIN 29-JUL-75 TC11 DECTAPE
580. YPTC BIN 29-OCT-75 11-DECTAPE FORMATTER
581. ZRXBE0 BIC 14-MAY-76 RX11 FLOPPY DIAGNOSTIC
582. ZRXAE0 BIC 14-MAY-76 RX11 FLOPPY RELIABILITY
583. DZDHMA BIN 12-FEB-76 DH11 DIAGNOSTIC
584. DZDHNA BIN 12-FEB-76 DH11 RELIABILITY
585. DZDHKC BIN 17-MAY-76 DM11-BB MODEM
586. DZLPLB BIN 1-MAR-76 LP20
587. ZRJAA0 BIC 1-MAY-76 RH11/RP04/5/6 MECH & READ/WRITE
588. ZRJBA0 BIN 1-MAY-76 RH11/RP04/5/6 FORMATTER
589. ZRJCA0 BIN 1-MAY-76 RH11/RP04/5/6 HEAD ALIGHMENT VERIFICATION
590. ZRJDA0 BIC 1-MAY-76 RH11/RP04/5/6 PERFORMANCE EXERCISER
591. ZRJGA0 BIC 1-MAY-76 RH11/RP04/5/6 DISKLESS CONTROLLER #1
592. ZRJHA0 BIC 1-MAY-76 RH11/RP04/5/6 DISKLESS CONTROLLER #2
593. ZRJIA0 BIC 1-MAY-76 RH11/RP04/5/6 FUNCTIONAL CONTROLLER #1
594. ZRJJA0 BIC 1-MAY-76 RH11/RP04/5/6 FUNCTIONAL CONTROLLER #2
595. SY2040 BIN 10-MAR-76 2040 FRONT END EXERCISER
596. ZQUXC1 BIN 14-MAY-76 CONFIGURATOR/LINKER
597. XQLAG0 LIB 14-MAY-76 MONITOR LIBRARY
598. XQLKA0 LIB 14-MAY-76 MODULE LIBRARY
599. DFQAAB BIN 25-FEB-76 1080 FRONT END EXERCISER
;PDP-10 DL10 PDP-11 DIAGNOSTICS
600. CMFAB0 BIC 2-JUN-75 MS-11 (MOS) & MF11-LP, MF11-P CORE PARITY
601. D8KA0 BIN 3-JUN-75 KG11 COMMUNICATIONS CRC TEST
602. ZDHAA1 BIC 3-JUN-75 DH11 STATIC LOGIC TEST
603. DZDHBB BIN 4-MAY-76 DH11 MEMORY TEST
604. ZDHCA2 BIC 3-JUN-75 DH11 RECIEVER & TRANSMITTER LOGIC TEST
605. DZDHDC BIN 10-MAY-76 DH11 SPEED SELECTION LOGIC TEST
606. ZDHEA2 BIC 3-JUN-75 DH11 CHARACTER LENGTH & BASIC DATA
607. ZDHFA1 BIC 3-JUN-75 DH11 SINGLE LINE DATA TEST
608. ZDHGB0 BIC 3-JUN-75 DH11 SINGLE LINE PARITY
609. ZDHHB0 BIC 3-JUN-75 DH11 AUTO-ECHO TEST
610. ZDHJB0 BIC 3-JUN-75 DH11 SINGLE LINE/ECHO/ONLINE
611. ZDHLA0 BIN 4-JUN-75 DH11 OVERLAY FOR INTERPROCESSOR TEST
612. ZDMDA0 BIC 3-JUN-75 DM11 BB MODEM CONTROL DIAGNOSTIC
613. DZDQAB BIN 24-MAY-76 DQ11 BASIC LOGIC TEST PART 1
614. DZDQCC BIN 24-MAY-76 DQ11 INTERRUPT LOGIC TEST
615. ZDQDA0 BIN 3-JUN-75 DQ11 RECIEVER & TRANSMITTER TEST
616. DZDQEC BIN 24-MAY-76 DQ11 MISC RX & TX + BCC TEST
617. ZDQGA0 BIN 3-JUN-75 DQ11 TRAIL PROGRAM & PARAMETER INPUT
618. ZITAB0 BIC 3-JUN-75 INTERPROCESSOR TEST PROGRAM (ITP)
619. DZKAQF BIN 27-JUL-76 PDP-11 POWER FAIL TEST
620. ZKLAD0 BIC 2-JUN-75 KL11/DL11-A TELETYPE TEST
621. ZQMAB0 BIC 2-JUN-75 MEMORY I/O EXERCISER
622. ZQMBG0 BIC 2-JUN-75 ZERO-124K MEMORY EXERCISER